A read-only, security-first way to turn existing ships into dependable sources of operational data
By Panagiotis Dimakis, Regional Account Manager for Moxa, CMA D. Argoudelis & Co S.A. | AMMITEC Gold Sponsor
Every shipowner wants better data from the engine room. Few want another connection into it.
In this year's CSN ICT report, AMMITEC's President described remote maintenance access as the widest and least guarded door in the maritime industry, while another ICT manager named edge devices such as routers, firewalls and VPN gateways as the attackers' primary initial point of entry. At the same time, technical teams need dependable data from vessels that were never designed to share it: counted by number of ships, the average vessel in the world fleet is more than 22 years old, according to UNCTAD.
IACS UR E26 and E27 are mandatory only for ships contracted for construction on or after 1 July 2024; for other ships they serve as non-mandatory guidance. Their principles still fit every retrofit: know what is connected, control who can reach it, detect what changes and be able to recover. The practical answer is a data path that only flows outward, proven on one vessel before it reaches the fleet.
Start with one operational question
A useful pilot begins with a decision someone owns. For example: can the technical team reliably compare auxiliary generator loading and running hours over time? Identify the signals, their owners and their interfaces before selecting any hardware, and agree how the data will feed a maintenance review.
1. Read-only by design
Moxa's EDR-G9010 secure router combines firewall, NAT, VPN and routing with industrial intrusion prevention and detection and deep packet inspection.
2. Connect existing equipment without replacing it
Serial device servers such as the NPort IA5000-G2 carry serial data over Ethernet, and Modbus gateways such as the MGate MB3170-G2 convert between Modbus RTU/ASCII and Modbus TCP. Both appear on Moxa's marine certified product list, with DNV approval for their 24 VDC models, and both comply with IEC 62443-4-2 Security Level 2 requirements. These devices solve connectivity, not meaning: register maps must be confirmed with equipment suppliers, and polling rates tested so that collection never loads the device it observes.
3. Keep the data when the satellite link drops
An onboard edge computer validates incoming records, attaches timestamps and holds data until the shore link returns. Moxa's marine-certified computers, including the BXP-C100, DRP-C100 and MC-3201 series, provide that platform; approvals such as DNV, IEC 60945 and IACS E10 vary by model. Storage, clock synchronisation and recovery after power loss must be designed and tested, and synchronisation should preserve the original capture time so a delayed upload is never mistaken for a change in machinery behaviour.
4. Separate the vessel into zones
Figure 1 arranges the pilot in three zones, following the reference architecture Moxa uses for smart ship remote monitoring. The operational zone holds the machinery and its interfaces, the management zone the edge computer and network management, and the security zone the boundary router and the DMZ.

Figure 1. Telemetry leaves the vessel in one direction; vendor support uses a separate, approved and time-limited path.
5. Be ready for the surveyor
As Moxa's maritime cybersecurity white paper summarises, E26 expects an up-to-date inventory of onboard systems, including software and firmware, maintained throughout the life of the ship. As one ICT manager notes in the CSN report, surveyors now inspect live asset inventories and active configuration backups. Moxa's MXview One discovers network devices and topology and centrally manages configurations and firmware, while MXsecurity aggregates security logs and real-time alerts.
Measure before you scale
Agree acceptance criteria before installation: the share of expected records captured, the length of data gaps, correct recovery after a deliberate link interruption, an inbound connection from shore that is refused, a vendor session that expires as configured, and the engineering time needed to investigate an abnormal reading. A pilot that passes becomes the fleet template.
|
Five questions before connecting machinery data ashore 1. Which operational decision will this data support, and who owns it? 2. Can anything on shore send a command back to the machinery? 3. Who can open a remote session, for how long, and who approves it? 4. If the satellite link fails for 24 hours, what is lost? 5. Could you hand a surveyor a current inventory, with firmware versions, today? |
|
Certified building blocks ▪ EDR-G9010 and EDR-8010 secure routers: DNV type approval for Security Profile 2, IACS UR E27 Rev.1 and IEC 61162-460 Edition 3.0, for the 460-gateway, 460-forwarder and 460-switch roles. ▪ EDS-4000/G4000 managed switches: IACS UR E27 Rev.1 and IEC 61162-460 Edition 3.0 for the 460-switch role. ▪ EDR-G9010 and EDS-4000/G4000: IEC 62443-4-2 Security Level 2 certified. Moxa operates an IEC 62443-4-1 certified secure development lifecycle. |
About CMA
CMA D. Argoudelis & Co S.A. is the official Moxa distributor in Greece and Cyprus. If you are planning a monitoring pilot, we would be glad to review the architecture with your team, or show it working at our Moxa showroom. www.cmagreece.com
Contact: Panagiotis Dimakis, Regional Account Manager for Moxa | This email address is being protected from spambots. You need JavaScript enabled to view it.
Association of Maritime Managers of Information Technology and Communications
E-mail: This email address is being protected from spambots. You need JavaScript enabled to view it., This email address is being protected from spambots. You need JavaScript enabled to view it.
Akti Miaouli 93, PIRAEUS 185 38
Copyright © 2017 AMMITEC. All Rights Reserved. Web Design by Web and Art Solutions